WIRING DIAGRAM
Millennium
TM
AIR COOLED SCREW LIQUID CHILLERS
(STYLE F)
Supersedes: 201.18-W1 (798)
Form 201.18-W1 (1298)
MODELS YCAS0130 THRU YCAS0230
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - Millennium

WIRING DIAGRAMMillennium TMAIR COOLED SCREW LIQUID CHILLERS(STYLE F)Supersedes: 201.18-W1 (798)Form 201.18-W1 (1298)MODELS YCAS0130 THRU YCAS0230

Page 2

YORK INTERNATIONAL10WIRING DIAGRAMACROSS-THE-LINE STARTNOTES:1. Field wiring to be in accordance with the currentedition of the National Electrical Co

Page 3 - NOMENCLATURE

FORM 201.18-W111YORK INTERNATIONALWIRING DIAGRAMACROSS-THE-LINE START

Page 4 - ELECTRICAL DATA

YORK INTERNATIONAL12FIG. 1 – CONTINUEDELEMENTARY DIAGRAM

Page 5

FORM 201.18-W113YORK INTERNATIONALCAUTION:No Controls (relays, etc.) shouldbe mounted in the Smart Panelenclosure or connected to powersupplies in the

Page 6 - ELECTRICAL DATA (Continued)

YORK INTERNATIONAL14WIRING DIAGRAMWYE-DELTA STARTNOTES:1. Field wiring to be in accordance with the currentedition of the National Electrical Code as

Page 7

FORM 201.18-W115YORK INTERNATIONALWIRING DIAGRAMWYE-DELTA START

Page 8

YORK INTERNATIONAL16FIG. 1 – CONTINUEDELEMENTARY DIAGRAM

Page 9 - CONTROL POWER SUPPLY

FORM 201.18-W117YORK INTERNATIONALCAUTION:No Controls (relays, etc.) shouldbe mounted in the Smart Panelenclosure or connected to powersupplies in the

Page 10 - WIRING DIAGRAM

YORK INTERNATIONAL18

Page 11

FORM 201.18-W119YORK INTERNATIONAL

Page 12 - ELEMENTARY DIAGRAM

YORK INTERNATIONAL2WARNINGHIGH VOLTAGEis used in the operation of this equipmentDEATH OR SERIOUS INJURYmay result if personnel fail to observe precaut

Page 13

YORK INTERNATIONAL20LEGEND

Page 14

FORM 201.18-W121YORK INTERNATIONAL

Page 15

YORK INTERNATIONAL22CONNECTION DIAGRAM (SYSTEM WIRING)

Page 16

FORM 201.18-W123YORK INTERNATIONALCOMPRESSOR TERMINAL BOX

Page 17

YORK INTERNATIONAL24MULTI-POINT POWER SUPPLY WIRING  STANDARD UNITSINGLE POINT POWER SUPPLY  WIRING WITH CIRCUIT BREAKERS

Page 18 - YORK INTERNATIONAL

FORM 201.18-W125YORK INTERNATIONALSINGLE POINT POWER WIRING WITH FIELD SUPPLIED CIRCUIT PROTECTIONSINGLE POINT POWER WIRING WITH CIRCUIT BREAKERS

Page 19 - FORM 201.18-W1

YORK INTERNATIONAL26ELECTRICAL POWER WIRING  OPTIONS: NON FUSED DISCONNECT SWITCHELECTRICAL POWER WIRING  OPTIONS: TERMINAL BLOCKSELECTRICAL POWER W

Page 20

FORM 201.18-W127YORK INTERNATIONAL

Page 22

FORM 201.18-W13YORK INTERNATIONALNOMENCLATUREThe Model Number denotes the following characteristics of the unit:YORK ChillerYC = YORK ChillerAir-Coole

Page 23 - COMPRESSOR TERMINAL BOX

YORK INTERNATIONAL4ELECTRICAL DATAMULTIPLE POINT POWER SUPPLY CONNECTION(Each of Two Field Provided Power Supply Circuits individually protected with

Page 24

FORM 201.18-W15YORK INTERNATIONALSYSTEM #2 FIELD-SUPPLIED WIRINGMODELVOLTS MIN NFD.E. FUSE C.B. FACTORY PROVIDED (LUGS) WIRE RANGE7COMPRESSOR FANSYCAS

Page 25

YORK INTERNATIONAL6OPTIONAL SINGLE-POINT POWER SUPPLY WITH INTERNAL CIRCUIT BREAKERS(One Field Provided Power Supply Circuit to the chiller. Field c

Page 26

FORM 201.18-W17YORK INTERNATIONALSYSTEM #1 SYSTEM #2MODELVOLTS FACTORYCOMPRESSOR DATA FAN DATAFACTORYCOMPRESSOR DATA FAN DATAYCASC.B. RLA Y-LRA X-LRA

Page 27

YORK INTERNATIONAL8OPTIONAL SINGLE POINT POWER SUPPLY CONNECTION TO FACTORY CIRCUIT BREAKER(One Field Provided Power Supply Circuit to the chiller. F

Page 28

FORM 201.18-W19YORK INTERNATIONALLEGENDACR-LINE ACROSS THE LINE STARTC.B. CIRCUIT BREAKERD.E. DUAL ELEMENT FUSEDISC SW DISCONNECT SWITCHFACT MOUNT CB