TECHNICAL GUIDE
SINGLE PIECE VARIABLE SPEED
AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
HEAT PUMP MODELS: AVY24 THRU 60 AND SVY48 THRU 60
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ari.org/aridirectory.
ISO9001
CertifiedQuality
ManagementSystem
256819-YTG-C-0506
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The new deluxe Affinity fan coil line offers the ultimate in
comfort, sound and application flexibility. The Affinity line of
fan coils utilize a whisper quiet variable speed motor that pro-
vides humidity control and the lowest operating cost in the
industry. The air handler is shipped ready to be installed in all
positions, upflow, downflow, horizontal left or right will, with
minor adjustments. No special kits are required to install this
deluxe product in any position. This top of the line product
was designed with the installer and homeowner in mind, easy
to install and quiet, efficient and unsurpassed comfort for the
end user.
All UPG air handlers and coils utilize a TXV to provide our
customers with the optimum performance and refrigerant
control required for 13+ systems. Air handlers can be ordered
with a R22 TXV factory installed that can be easily converted
to R410A by changing the bolt-on TXV. Air handlers are also
available with “Flex-coils” without a factory installed metering
device. For added flexibility a R22 or R410A TXV can be field
installed to meet your refrigerant choice.
FEATURES
Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today’s high efficient product. The UPG
bolt-on TXV provides the added flexibility to convert the air
handler to the required refrigerant. The UPG TXV is a true
bolt-on which does not require brazing to replace or install.
MicroBlue
TM
Coated Fins - All air handler coils are treated
with the MicroBlue
TM
hydrophilic coating to enhance the
removal of condensate during the refrigeration cycle and
reduce the possibility of water blow-off. The MicroBlue
TM
coating also reduces the growth of germ causing microbes
for a healthier home environment.
Insulated Cabinet - All air handler cabinets are thermally
insulated with 1” foil faced insulation (R-4.2) to prevent
sweating. For applications in extreme humidity conditions an
optional, field installed, external insulating wrap kit is also
available.
Durable Finish Inside and Out - Air handler casings are
made of pre-painted galvanized steel which provides a better
paint to steel bond that resists corrosion and rust creep. All
internal coil sheet metal parts are made of G90 pre-painted
steel i.e. triangular plates, top plates, horizontal supports etc.
Coil header plates are not painted due to the brazing process
during production. The coil header plates are treated after the
brazing process with a corrosion resistant spray to reduce the
probability of rust.
New 4 HK Heat Kit - Installation friendly, easy service, more
robust, unique to new design.
ECM Variable Speed Motor - Designed for efficient, quiet
operation with added indoor comfort control. With the use of a
humidistat the motor will monitor the humidity in the home
and automatically keep the desired humidity level in both win-
ter and summer seasons. The ECM motor utilizes only 24%
of the energy used by standard blower motors which will
reduce your overall heating and cooling costs.
ClimaTrak - Installers can set an operating cycle for the ECM
motor that works best in a particular climate. Homeowners
benefit from an operating cycle that maximizes their indoor
comfort level regardless of whether they live in a dry, temper-
ate, or humid climate.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - TECHNICAL GUIDE

TECHNICAL GUIDESINGLE PIECE VARIABLE SPEEDAIR HANDLERSFOR USE WITH SPLIT-SYSTEMCOOLING & HEAT PUMPSHEAT PUMP MODELS: AVY24 THRU 60 AND SVY48 THRU

Page 2 - COIL TECHNICAL DATA

256819-YTG-C-05062 Unitary Products GroupDIMENSIONS 10-3/8”FCIRCUITBREAKERPANELBOTTOM INLETDIMENSIONSDRAIN PAN CONNECTIONSFOR HORIZONTAL APPLICATIONSB

Page 3 - Cooling Air Flow Data

256819-YTG-C-0506Unitary Products Group 3COOLING CAPACITYModel Coil Rated CFMEntering Air °F (Dry / Wet Bulb)MBH@ Evaporator Temperature and Correspon

Page 4 - Heating Air Flow Data

256819-YTG-C-05064 Unitary Products GroupHeating Air Flow DataHIGH / LOW HEAT CFM24B Air Handler 36C Air HandlerJUMPER SETTINGS CFM CFM CFM CFMHigh L

Page 5 - Unitary Products Group 5

256819-YTG-C-0506Unitary Products Group 5* May be 0 (no breaker) or 1 (with breaker). Electrical Data - 1 Ø - 208/230-1-60Models Heat Kits*Max.Static

Page 6 - 6 Unitary Products Group

256819-YTG-C-05066 Unitary Products Group* May be 0 (no breaker) or 1 (with breaker). Electrical Data - (For Single Source Power Supply) - Copper Wire

Page 7 - LIMITATIONS

256819-YTG-C-0506Unitary Products Group 7ACCESSORIESRefer to Price Manual for specific model numbers.TXV Kits - TXV kits are available for “Flex-coil”

Page 8 - TYPICAL APPLICATIONS

Subject to change without notice. Printed in U.S.A. 256819-YTG-C-0506Copyright © by York International Corp. 2006. All rights reserved. Supersedes

Commentaires sur ces manuels

Pas de commentaire