TECHNICAL GUIDESPLIT-SYSTEM AIR CONDITIONERS14.5 SEER – R-410AMODELS:TCGF24 THRU 60(2 THRU 5 NOMINAL TONS, 1 PHASE)Due to continuous product improveme
413434-LTG-E-090910 Johnson Controls Unitary ProductsTCGF30S41S1T*9X*C16 FC/MC/PC48C 21 1075 30.8 23.4 16.00 13.25T*9X*C20 FC/MC/PC48C 21 745 29.0 20.
413434-LTG-E-0909Johnson Controls Unitary Products 11TCGF36S41S1T*(8,L)X*B12 FC/MC/PC35B 17 1290 34.6 25.8 15.25 12.75T*(8,L)X*C16 FC/MC/PC35C 21 1105
413434-LTG-E-090912 Johnson Controls Unitary ProductsTCGF36S41S1L*(8,L)C*C20 FC/MC/PC43C 21 1190 35.0 25.6 15.75 13.00 (L*9C/T*9V)*C16 FC/MC/PC4
413434-LTG-E-0909Johnson Controls Unitary Products 13TCGF42S41S1T*9X*D20 HD48 24 1460 47.5 27.4 14.75 12.50T*(8,L)X*C16 UC48C 21 1400 40.0 29.8 14.90
413434-LTG-E-090914 Johnson Controls Unitary ProductsTCGF48S41S1T*(8,L)X*C16 FC/MC/PC48C 21 1600 47.0 33.8 14.50 12.25T*(8,L)X*C20 FC/MC/PC48C 21 1660
413434-LTG-E-0909Johnson Controls Unitary Products 15TCGF48S41S1(L*9C/T*9V)*C16 HD60 21 1590 47.0 33.4 14.75 12.50 (L*9C/T*9V)*C20 HD60 21 1655
413434-LTG-E-090916 Johnson Controls Unitary ProductsACCESSORIESRefer to Price Manual for specific model numbers.Off Cycle Timer Delay - Provides a 5-
413434-LTG-E-0909Johnson Controls Unitary Products 17Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera
413434-LTG-E-090918 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*A12 FC/MC/PC24A 1.04 1.07 0.92T*(8,L)X*B12 FC/MC/PC24B 1.05 1
413434-LTG-E-0909Johnson Controls Unitary Products 19Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera
413434-LTG-E-09092 Johnson Controls Unitary ProductsAll dimensions are in inches. They are subject to change with-out notice. Certified dimensions wil
413434-LTG-E-090920 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*A12 FC/MC/PC30A 1.00 1.01 0.94T*(8,L)X*B12 FC/MC/PC30B 0.99 0
413434-LTG-E-0909Johnson Controls Unitary Products 21Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera
413434-LTG-E-090922 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*B12 FC/MC/PC35B 1.01 1.03 0.95T*(8,L)X*C16 FC/MC/PC35C 0.99 0
413434-LTG-E-0909Johnson Controls Unitary Products 23Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera
413434-LTG-E-090924 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*B12 FC/MC/PC43B 0.99 0.98 0.94T*(8,L)X*C16 FC/MC/PC43C 1.02 1
413434-LTG-E-0909Johnson Controls Unitary Products 25Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera
413434-LTG-E-090926 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*C16 FC/MC/PC48C 1.01 1.02 0.96T*(8,L)X*C20 FC/MC/PC48C 1.01 1
413434-LTG-E-0909Johnson Controls Unitary Products 27Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera
Subject to change without notice. Published in U.S.A. 413434-LTG-E-0909Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 41
413434-LTG-E-0909Johnson Controls Unitary Products 3PROCEDURES:1. Unit factory charge listed on the unit nameplate includes refrigerant for the conden
413434-LTG-E-09094 Johnson Controls Unitary ProductsCOOLING CAPACITY - With Air Handler CoilsUNITMODELAIR HANDLERCOILMODEL1COOLINGMODEL WRATEDCFMNET M
413434-LTG-E-0909Johnson Controls Unitary Products 514.5 SEER AC WITH MV - VARIABLE SPEED (Continued)TCGF36S41S1MV12B 17 FC/MC35B 1200 35.0 25.8 15.00
413434-LTG-E-09096 Johnson Controls Unitary Products— = Not applicable.TCGF30S41S1AHP36 21 – 1000 29.6 21.4 14.30 12.20 AHX30 17 – 1025 29.6 22.0 15.
413434-LTG-E-0909Johnson Controls Unitary Products 7COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and CoilsUNIT MODELFURNACE**COILMODE
413434-LTG-E-09098 Johnson Controls Unitary ProductsCOOLING CAPACITY - With High Efficiency Motor FurnacesUNITMODELFURNACE MODELCOILMODEL1WCOOLINGRATE
413434-LTG-E-0909Johnson Controls Unitary Products 9TCGF24S41S1(L*9C/T*9V)*B12 FC/MC/PC35B 17 815 24.0 17.0 15.75 13.25 L*(8,L)C*A12 FC/MC/PC36A
Commentaires sur ces manuels