TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
14.5 SEER – R-410A
MODELS:
TCGF24 THRU 60
(2 THRU 5 NOMINAL TONS, 1 PHASE)
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
10-year limited compressor warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
LISTED
413434-LTG-E-0909
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 14.5 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
Quality Condenser Coils - The coil is constructed of alumi-
num microchannel tubing and enhanced aluminum fins for
increased efficiency and corrosion protection.
Protected Compressor - The compressor is internally pro-
tected against high pressure and temperature and externally
by a factory installed high pressure switch. This protects the
compressor if undesirable operating conditions occur. A liq-
uid line filter-drier further protects the compressor.
Durable Finish - The cabinet is made of pre-painted steel.
The pre-treated galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
Top Discharge - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
Low Operating Sound Level - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolated
compressor mounts minimize compressor operating sounds.
Low Maintenance - Long life permanently lubricated motor-
bearings need no annual servicing.
Easy Service Access - Fully exposed refrigerant connec-
tions, and a single panel covering the electrical controls
make for easy servicing of the unit.
Secured Service Valves - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - TECHNICAL GUIDE

TECHNICAL GUIDESPLIT-SYSTEM AIR CONDITIONERS14.5 SEER – R-410AMODELS:TCGF24 THRU 60(2 THRU 5 NOMINAL TONS, 1 PHASE)Due to continuous product improveme

Page 2 - Physical and Electrical Data

413434-LTG-E-090910 Johnson Controls Unitary ProductsTCGF30S41S1T*9X*C16 FC/MC/PC48C 21 1075 30.8 23.4 16.00 13.25T*9X*C20 FC/MC/PC48C 21 745 29.0 20.

Page 3

413434-LTG-E-0909Johnson Controls Unitary Products 11TCGF36S41S1T*(8,L)X*B12 FC/MC/PC35B 17 1290 34.6 25.8 15.25 12.75T*(8,L)X*C16 FC/MC/PC35C 21 1105

Page 4

413434-LTG-E-090912 Johnson Controls Unitary ProductsTCGF36S41S1L*(8,L)C*C20 FC/MC/PC43C 21 1190 35.0 25.6 15.75 13.00 (L*9C/T*9V)*C16 FC/MC/PC4

Page 5

413434-LTG-E-0909Johnson Controls Unitary Products 13TCGF42S41S1T*9X*D20 HD48 24 1460 47.5 27.4 14.75 12.50T*(8,L)X*C16 UC48C 21 1400 40.0 29.8 14.90

Page 6

413434-LTG-E-090914 Johnson Controls Unitary ProductsTCGF48S41S1T*(8,L)X*C16 FC/MC/PC48C 21 1600 47.0 33.8 14.50 12.25T*(8,L)X*C20 FC/MC/PC48C 21 1660

Page 7

413434-LTG-E-0909Johnson Controls Unitary Products 15TCGF48S41S1(L*9C/T*9V)*C16 HD60 21 1590 47.0 33.4 14.75 12.50 (L*9C/T*9V)*C20 HD60 21 1655

Page 8

413434-LTG-E-090916 Johnson Controls Unitary ProductsACCESSORIESRefer to Price Manual for specific model numbers.Off Cycle Timer Delay - Provides a 5-

Page 9

413434-LTG-E-0909Johnson Controls Unitary Products 17Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 10 - 413434-LTG-E-0909

413434-LTG-E-090918 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*A12 FC/MC/PC24A 1.04 1.07 0.92T*(8,L)X*B12 FC/MC/PC24B 1.05 1

Page 11

413434-LTG-E-0909Johnson Controls Unitary Products 19Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 12

413434-LTG-E-09092 Johnson Controls Unitary ProductsAll dimensions are in inches. They are subject to change with-out notice. Certified dimensions wil

Page 13

413434-LTG-E-090920 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*A12 FC/MC/PC30A 1.00 1.01 0.94T*(8,L)X*B12 FC/MC/PC30B 0.99 0

Page 14

413434-LTG-E-0909Johnson Controls Unitary Products 21Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 15

413434-LTG-E-090922 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*B12 FC/MC/PC35B 1.01 1.03 0.95T*(8,L)X*C16 FC/MC/PC35C 0.99 0

Page 16 - TYPICAL FIELD WIRING

413434-LTG-E-0909Johnson Controls Unitary Products 23Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 17 - COOLING PERFORMANCE DATA

413434-LTG-E-090924 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*B12 FC/MC/PC43B 0.99 0.98 0.94T*(8,L)X*C16 FC/MC/PC43C 1.02 1

Page 18

413434-LTG-E-0909Johnson Controls Unitary Products 25Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 19

413434-LTG-E-090926 Johnson Controls Unitary ProductsFurnaces Coils T.C. S.C. KWT*(8,L)X*C16 FC/MC/PC48C 1.01 1.02 0.96T*(8,L)X*C20 FC/MC/PC48C 1.01 1

Page 20

413434-LTG-E-0909Johnson Controls Unitary Products 27Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 21

Subject to change without notice. Published in U.S.A. 413434-LTG-E-0909Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 41

Page 22

413434-LTG-E-0909Johnson Controls Unitary Products 3PROCEDURES:1. Unit factory charge listed on the unit nameplate includes refrigerant for the conden

Page 23

413434-LTG-E-09094 Johnson Controls Unitary ProductsCOOLING CAPACITY - With Air Handler CoilsUNITMODELAIR HANDLERCOILMODEL1COOLINGMODEL WRATEDCFMNET M

Page 24

413434-LTG-E-0909Johnson Controls Unitary Products 514.5 SEER AC WITH MV - VARIABLE SPEED (Continued)TCGF36S41S1MV12B 17 FC/MC35B 1200 35.0 25.8 15.00

Page 25

413434-LTG-E-09096 Johnson Controls Unitary Products— = Not applicable.TCGF30S41S1AHP36 21 – 1000 29.6 21.4 14.30 12.20 AHX30 17 – 1025 29.6 22.0 15.

Page 26

413434-LTG-E-0909Johnson Controls Unitary Products 7COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and CoilsUNIT MODELFURNACE**COILMODE

Page 27

413434-LTG-E-09098 Johnson Controls Unitary ProductsCOOLING CAPACITY - With High Efficiency Motor FurnacesUNITMODELFURNACE MODELCOILMODEL1WCOOLINGRATE

Page 28 - 5005 York Drive

413434-LTG-E-0909Johnson Controls Unitary Products 9TCGF24S41S1(L*9C/T*9V)*B12 FC/MC/PC35B 17 815 24.0 17.0 15.75 13.25 L*(8,L)C*A12 FC/MC/PC36A